4. If you are going to cover screen door with paneling or other
materials, allow access (suitable holes or a plug) to screws
for servicing.
5. Use supplied 1/8” nex key and a 7/16” wrench to remove silver
shipping brackets attached to slat and screen case.
6. Picture surface should hang freely. (Fig. 2) Remove any tape
left hanging on back of fabric. Bottom edge should be
positioned between bottom edge of case and center of roller.
7. Install electrical hook up that applies to your unit. Unit should
be installed by a qualiied electrician.
NOTE: Must be installed in accordance with the requirements
of the Local Building Codes, the Canadian Electrical Code
(CEC), CAN/CSA C22.1 and the National Electric Code (NEC),
NFPA 70.
8. Test installation by carefully running picture surface “up” and
down” several times. Be prepared to stop screen. Fabric door
must open freely to 90˚.
9. Make sure picture surface, when rolled down, has a full wrap
around roller. No part of roller should be exposed. Fabric door
and picture surface will drop simultaneously when switch is
pressed “down”. Door will close simultaneously with picture
surface as picture surface rolls into case.
1. Press switch “down” so that fabric door opens (Fig. 2).
2. Remove screws (2) located on each bumper bracket.
NOTE: The access door is slotted on one edge, permitting the
slotted section to it over the access panel clips on inside of
case.
3. Place access panel so slot can be pushed over clips.
Holes in access panel brackets should align with bumper
bracket holes.
4. Replace screws.
5. Make sure there is approximately 316" clearance around
access door. Keep paint, plaster, tile or mastic out of hinge.
Fit access panel so it can be removed for maintenance.
The picture surface drop, and the opening and closing of the fabric door, are controlled automatically by limit switches which have been
preset at Da-Lite. When the picture surface is moving upward, it is controlled by a limit switch that shuts of when the door closes. The height
for tensioned screens are adjusted at Da-Lite, changing the height of screen will change the tension on fabric and cause the screen to hang
improperly. Do not adjust.
Installation (Continued)
Access Door Installation
Screen Adjustment
Figure 2
Cross Section
Access Panel
Screw (Painted)
Access Panel
False Top
Picture
Surface
Access
Panel Clip
Fabric Door
Bumper
Bracket